Input P70 ED
54
Group
Parameter
Description
Machine type
User level
Setting range
Set value
8
815 Motor starting method after mains on
1 = sinus method
2 = impulse method
1, 2, 3 C 1 - 2 1
880 Max. starting current [A] 1, 2, 3 C 1 - 20 10
884 Proportional amplifi cation of speed
control of sewing motor
1, 2, 3 B 1 - 24 18
885 Integral amplifi cation of speed control
of sewing motor
1, 2, 3 C 10 - 80 50
886 Proportional amplifi cation of positioning
controller for sewing motor
1, 2, 3 C 1 - 15 8
887 Differential amplifi cation of positioning
controller for sewing motor
1, 2, 3 C 1 - 15 8
889 Time for positioning control in [ms],
0 = always
1, 2, 3 C 0 - 2500 200
890 Proportional amplifi cation of stop brake 1, 2, 3, 4, 5 C 1 - 10 5
897* MINI-motor variant
1 = long, 0 = short
1, 2, 3 C 0 - 1 1
898 Motor current limitation
ON = 15A,
OFF = 10A
1, 2, 3 C ON - OFF OFF
9
900 Proportional amplifi cation of speed
controller during trimming
1, 2, 3 B 1 - 30 18
901 Trimming release-speed 1, 2, 3 B 30 - 500 300
909 Thread puller on / off 1, 2, 3 B ON - OFF OFF
910 Thread puller delay time [ms] 1, 2, 3 B 10 - 2550 100
933 Switchover of display on screen
ON = diagnosis display
OFF = standard display
1, 2, 3 C ON - OFF OFF
* = These parameters remain unchanged when the set parameter values are reset,
see Chapter 10.01 Reset / Cold start.