PHILIPS 4000 and 3000 05 SERVICE MODE
13/18
Level 2 (Input)
Startcondition:NOBU,NOdragdrawer,dooropenand
No Water sensor
LED INDICATION
Led
NoBeans
Led
NoWater
Led
GenAlarm
Led Dreg
drawer full
OFF ON ON ON
Finishcondition:WithBU,DragDrawer,doorclosedand
Tank
LED INDICATION
Led
NoBeans
Led
NoWater
Led
GenAlarm
Led Dreg
drawer full
OFF OFF OFF OFF
InsertafullWaterTank
Action by user LED INDICATION
Led
NoBeans
Led
NoWater
Led
GenAlarm
Led Dreg
drawer full
Switch off Red Leds NoWater NA OFF NA NA
ERROR: Led NoWater remains on, check the capacitive
sensor(xing)andthewiring(JP23)
NA ON NA NA
Insert the Brew Unit
Action by user LED INDICATION
Led
NoBeans
Led
NoWater
Led
GenAlarm
Led Dreg
drawer full
Switch off Red Leds GenAlarm NA NA OFF NA
ERROR:LedGenAlarmremainson,checktheBUpresen-
ceMicroswitchandthewiring(JP16).
NA NA ON NA
Insert Dreg drawer and close the service door
Action by user LED INDICATION
Led
NoBeans
Led
NoWater
Led
GenAlarm
Led Dreg
drawer full
Switch off Red Led Dreg drawer full NA NA NA OFF
ERROR:LedDregdrawerfullremainson,checktheMi-
croswitchforthedoorandthewiring(JP14).
NOTE: without the Dreg drawer correctly inserted the in-
dication cannot change!
NA NA NA ON
Finish condition:NOBU,NOdragdrawer,
door open and No Water sensor
LED INDICATION
Led
NoBeans
Led
NoWater
Led
GenAlarm
Led Dreg
drawer full
Led
Descale
Led
Rinsing
OFF OFF OFF OFF OFF OFF
Press Hot Water Button
Action by user LED INDICATION
Led Steam Button Led Hot-Water Button
Switch on green Led under the Hot Water
button
OFF ON
ERROR:LedHot-Waterremainsoff,check
theinterfaceboardandatcable(JP21)
OFF OFF
Press BUTTON Stand-By to move to the next screen