1.3 Installation of FL MGUARD RS4000/RS2000
1.3.1 Mounting/removal
Mounting The device is ready to operate when it is supplied. The recommended sequence for mount-
ing and connection is as follows:
Mount the FL MGUARD RS4000/RS2000 on a grounded 35 mm DIN rail according to
DINEN60715.
Figure 1-3 Mounting the FL MGUARD RS4000/RS2000 on a DIN rail
Attach the top snap-on foot of the FL MGUARD RS4000/RS2000 to the DIN rail and
then press the FL MGUARD RS4000/RS2000 down towards the DIN rail until it engag-
es with a click.
Removal Remove or disconnect the connections.
To remove the FL MGUARD RS4000/RS2000 from the DIN rail, insert a screwdriver
horizontally in the locking slide under the housing, pull it down – without tilting the
screwdriver – and then pull up the FL MGUARD RS4000/RS2000.