4.3 Installation of TC MGUARD RS4000/RS2000 4G
4.3.1 Mounting/removal
Mounting The device is ready to operate when it is supplied. The recommended sequence for mount-
ing and connection is as follows:
Mount the TC MGUARD RS4000/RS2000 4G on a grounded 35 mm DIN rail according
to DIN EN 60715.
Figure 4-3 Mounting the TC MGUARD RS4000/RS2000 4G on a DIN rail
Attach the top snap-on foot of the TC MGUARD RS4000/RS2000 4G to the DIN rail
and then press the TC MGUARD RS4000/RS2000 4G down towards the DIN rail until
it engages with a click.
Removal Remove or disconnect the connections.
To remove the TC MGUARD RS4000/RS2000 4G from the DIN rail, insert a screw-
driver horizontally in the locking slide under the housing, pull it down – without tilting the
screwdriver – and then pull up the TC MGUARD RS4000/RS2000 4G.
NOTE: Device damage
Only mount and remove devices when the power supply is disconnected.