EasyManua.ls Logo

Phoenix Contact FL MGUARD RS2000 TX/TX VPN - Page 64

Phoenix Contact FL MGUARD RS2000 TX/TX VPN
270 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
TC MGUARD RS4000/RS2000 3G
64
PHOENIX CONTACT 105656_en_05
3.3.6 Connecting the supply voltage
The supply voltage is connected via a plug-in screw terminal block, which is located on the
top of the device.
Figure 3-7 Connecting the supply voltage (TC MGUARD RS4000 3G)
The TC MGUARD RS4000 3G has a redundant supply voltage. If you only connect one
supply voltage, you will get an error message.
Remove the plug-in screw terminal blocks for the power supply and the service con-
tacts.
Wire the supply voltage lines of the X4 mGuard screw terminal block. Tighten the
screws on the screw terminal blocks with 0.5 ... 0.8 Nm.
Insert the plug-in screw terminal blocks into the intended sockets on the top of the de-
vice.
Status LED P1 lights up green when the supply voltage has been connected properly. On
the TC MGUARD RS4000 3G, the status indicator P2 also lights up if there is a redundant
supply voltage connection.
The device boots the firmware. The Stat LED flashes green. The device is ready for opera-
tion as soon as the Ethernet socket LEDs light up. Additionally, the P1/P2 LEDs light up
green and Stat LED flashes green at heartbeat.
Redundant voltage supply (TC MGUARD RS4000 3G)
A redundant supply voltage can be connected. Both inputs are isolated. The load is not dis-
tributed. With a redundant supply, the power supply unit with the higher output voltage sup-
plies the TC MGUARD RS4000 3G alone. The supply voltage is electrically isolated from
the housing.
WARNING: The device is designed for operation with a DC voltage of
11 V DC ... 36 V DC/SELV, 800 mA maximum.
Therefore, only SELV circuits with voltage limitations according to
IEC 60950/EN 60950/VDE 0805 may be connected to the supply connections and the
signal contact.
Table 3-3 Supply voltage TC MGUARD RS4000/RS2000 3G
TC MGUARD RS4000 3G TC MGUARD RS2000 3G

Table of Contents

Related product manuals