TC MGUARD RS4000/RS2000 3G
72
PHOENIX CONTACT 105656_en_05
• When the Stat LED has gone out, slowly press the Reset button again six times.
If successful, the Stat LED lights up green.
If unsuccessful, the Err LED lights up red.
If successful, the device restarts after two seconds and switches to Router mode. The de-
vice can then be reached again under the corresponding address.
mGuard firmware version 8.4.0 or later
• After the recovery procedure has finished, log in to the web interface of the device.
• Open the menu Management >> Configuration Profiles.
• Choose the configuration profile, generated during the recovery procedure: „Recov-
ery-DATE“ (e.g. “Recovery-2016.12.01-18:02:50).
• Click on the Icon „Edit profile“ to analyze the configuration profile and to restore it
with or without changes.
• Click on the Icon „Save“ to apply the changes.