C-863.12 Mercury Controller MS249E Version: 1.2.1 147
▪ 101=Current Phase B [mA]
Note: The analog inputs for the record option 81 can be
the Input 1 to Input 4 lines of the I/O socket (p. 266). Use
the identifiers 1 to 4 for these data sources.
Data source identifiers 5 and 6 refer to the inputs for the
joystick's axis and button:
5 = Axis 1 of the joystick
6 = Button 1 of the joystick
DRC? (Get Data Recorder Configuration)
Queries the settings for the data to be recorded.
<RecTableID>: is a data recorder table of the controller; if
this entry is not specified, the response will contain the
settings for all tables.
The current DRC settings:
{<RecTableID>"="<Source> <RecOption> LF}
where
<Source>: is the data source, for example, an axis or a
channel of the controller. The source type depends on the
record option.
<RecOption>: is the type of data to be recorded (record
option).
The available record options can be queried with HDR? (p.
157).
DRL? (Get Number of Recorded Points)
Reads the number of points comprised by the last
recording.
<RecTableID> is one data recorder table of the controller