The shutdown NG history is displayed in "INFORMATION" of the Factory menu.
The data on the past eight shutdowns are stored in memory.
Diagnosis Method in Shutdown
1 OSD display of the Shutdown NG history
2 Shutdown NG history by RS-232C command "GSD"
IN
NG
F
1WDE
2WIDE
3MDOULE
4MAIN IIC
I
5 –––
–––
–––
–––
6
7
8
O
INFO
––S1 I N4– 02– ∗2NT#1
Order Data Contents Size
1 The latest "SD INFO" 1 byte
2 First latest "SD INFO" 1 byte
3 Second latest "SD INFO" 1 byte
4 Third latest "SD INFO" 1 byte
5 Fourth latest "SD INFO" 1 byte
6 Fifth latest "SD INFO" 1 byte
7 Sixth latest "SD INFO" 1 byte
8 Seventh latest "SD INFO" 1 byte
OSD DisplayShutdown Point
PANELPanel microcomputer communication failure
MOD IICModule IIC communication failure
DEWCondensation
TEMPTemperature abnormality
FANFAN abnormality
MODULEModule microcomputer communication failure
WIDEWide microcomputer communication failure
MAIN IICMain IIC communication failure
AUDIOAUDIO failure
OSD DataShutdown Point
1Panel microcomputer communication failure
2Module IIC communication failure
3Condensation
4Temperature abnormality
5FAN abnormality
6Module microcomputer communication failure
7Wide microcomputer communication failure
8Main IIC communication failure
9AUDIO failure