FIG-1
FIG-3
FIG-2
FIG-4
29
ELECTRONICS
USER INTERFACE PARAMETERS
FIG-1 - SEMI SHOTS PARAMETER
This sets the number of shots in semi-automatic
required at the KICK IN rate before ramping starts.
This parameter can be set between 3 and 9 pulls
in 1 pull increments.
FIG-2 - KICK IN PARAMETER
This sets the rate at which the trigger has to be
pulled in order to start ramping.
This parameter can be set between 3.3 and 10.0
pulls per second in 0.1 increments.
FIG-3 - SUSTAIN PARAMETER
This sets the rate at which the trigger must be
continually pulled in order to maintain ramping.
This parameter can be set between 3.3 and 10.0
pulls per second in 0.1 increments.
FIG-4 - RESTART PARAMETER
This sets the amount of time that can elapse, after
the nal ramped shot is red before ramping is
reset and must be restarted again by meeting the
dened conditions (above).
This parameter can be set between 0.0 and 1.0
seconds in 0.1 increments.