76
POSEIDON M28 USER MANUAL
Operating conditions
Normal altitude range: 0 to 3,000 m / 10,000 ft above sea level
Operating temperature: -20°C to +50°C / -4°F to +122°F
Storage temperature: -20°C to +50°C / -4°F to +122°F
Do not leave the dive computer in direct sunlight.
Depth gauge
Temperature compensated pressure sensor
Maximum depth of operation: 200 m / 656 ft (complying with EN 13319)
Maximum static pressure: 20 bar (complying with EN 13319 and ISO 6425)
Accuracy: ± 1% of full scale or better from 0 to 200 m / 656 ft at 20°C / 68°F
(complying with EN 13319)
Depth display range: 0 to 300 m / 984 ft
International design registration (WIPO) DM/093447 for design of computer M28,
CPOD and graphic interface.