G2000e/G3000e/G6000e User’s Manual Chapter 3: Operations and Settings
27
Main Menu
Description
DUMP MODE
In dump mode, the printer will print out the data (print commands) that are
sent from PC or other devices, instead of executing the print task.
Options: ENABLE, DISABLE
Default: DISABLE
CALIB
LENGTH
Set media feeding length for calibration.
Default 200, the unit is mm.
Calibration length shall be set to at least twice of the height of one label.
STANDALONE
MODE
Standalone function is available when the printer is connected to a keyboard
or scanner. Label form needs to be downloaded to the FLASH ROM in
advance.
DELETE
FORMS
Clear the forms downloaded to the printer.
DELETE
IMAGES
Clear the graphics downloaded to the printer.
LOAD
DEFAULT
Restore factory default settings.
RFID
CALIBRATION
Automatically finds the optimal RFID READ/WRITE position, prior to RFID
calibration, a proper media calibration is required.
RFID POWER
RFID READ/WRITE POWER, the unit is dBm.
Range: 1-27
Default: 25
RFID OFFSET
Optimal distance between RFID READ/WRITE position and the leading edge
of the label, this value can be automatically set by performing RFID
calibration. Select this option to manually adjust the value.
READ RFID
DATA
Read data from the EPC block of the RFID tag.
RFID
FUNCTION
Options: ENABLE, DISABLE
Default: ENABLE
RFID, No. OF
TRIES
RFID encoding maximum retry times to complete a successful encoding job.
Default: 00, Range 00 to 200
Both 00 and 01 means try 1 time after an RFID error.
RESET
PASSWORD
Set password for network settings and enable/disable RFID function.
Default password: 0000
PASSWORD
Options: ENABLE, DISABLE
Default: DISABLE
Input default password: 0000 to enter the setting.