Interval Maintenance work Personnel
Once a year Visual check, whether all fan exhausts are clean and the fans are
properly working.
n If required, clean the fan exhausts with a dry cloth or if necessary
use a vacuum cleaner.
Instructed person
Check whether all fans inside the electrical cabinet are operating
accordingly.
n Use a sheet of paper and keep it in front of the fans inside the
electical cabinet to check if it is moving.
Instructed person
Check whether all interface cables are installed properly in their
respective sockets.
n Before re-plugging loose cables, properly shut down the control
unit and machine and secure against inadvertent restart.
n Unplug the respective cables and re-plug them afterwards.
n Follow instructions in
Ä
Chapter 7.3 “Measures after mainte-
nance” on page 88.
Instructed person
Make a backup of the data.
n For the exact procedure to make the backups see
Ä
Chapter 2.10 “Data safety” on page 20.
Skilled electrician
7.3 Measures after maintenance
Perform the following steps after completing maintenance and
before switching on the control unit and the machine:
1. Check all previously loosened screw connections for a tight
fit.
2. Check whether all previously removed protective devices and
covers are properly installed again.
3. Make sure that all tools, materials and other equipment used
were removed again from the cabinet.
4. Clean up work area and remove any substances left over,
such as fluids, cleaning material or the like. Dispose them
according to the current applicable regulations.
5. Make sure that all safety features on the control unit and
relating to the machine are fully functional.
Schedule
PA 8000 EL CNC control unit
Maintenance
24.09.2015 | 88