Page 32 of 49 Instructions/Parts list Multi-Dumper MCE400 updated: 04.2021
5,3 EMR Switch Redundancy
Shutdown Interlock
Shutdown EM-Brake
Either or both Emergency
Reverse input switches are
inoperative, resulting in an
invalid state.
There is dirt or moisture in
the switches.
The emergency reverse NO and
NC switches are in an invalid
state.
Address the possible
causes, then cycle the
keyswitch.
5,8
Stall Detected
Shutdown EM-Brake
Shutdown Throttle
Shutdown Motor
The motor has stalled.
The controller did not detect
motor movement.
Cycle the keyswitch. If the
fault is still active, call
costumer support.
7,7 Supervision
Shutdown Motor
Shutdown Main Contactor
Shutdown EM-Brake
Shutdown Throttle
Shutdown Interlock
Shutdown Driver1
Shutdown Driver2
Shutdown Driver3
The controller failed. Internal controller failure.
Cycle the keyswitch.
8,8
Internal Hardware
Shutdown Motor
Shutdown Main Contactor
Shutdown EM-Brake
Shutdown Throttle
An internal controller fault
occurred.
The controller detected an
internal fault.
Cycle the keyswitch.
8,10 Parameter Out of Range
Shutdown Motor
Shutdown Main Contactor
Shutdown EM-Brake
Shutdown Throttle
A parameter is set to an invalid
value.
The controller detects an invalid
parameter value.
Contact costumer support
9,4
Emer Rev Timeout
Shutdown Throttle
Shutdown EM-Brake
Emergency braking has
ended because the action
exceeded the emergency
braking time limit.
The emergency brake
lever is caught in the on
position.
An emergency reverse
operation stopped when it
reached the specified time limit.
Turn off the emergency
reverse switch.