PR4000 9mt 4x1000W METAL HALIDE
35
TL073-11-02-03
01-02-2011
Check that the push button circuit breaker (Fig. 8-A) hydraulic gear box engines protection place
on the frontal board are in “ON” position.
On the command panel is placed the lever that allows to raise and to lower the telescopic mast in
easy and comfortable way (Fig. 8-D).
The attainment of the maximum height is evidenced by a red wrap placed on the base of the mast.
Proceed to light the lamps through the relatives circuit breakers placed on the front panel of the
lighting tower.
Light the first lamp (Fig. 8-C) and allow 2 minutes for it to warm up, then light the next lamps,
remembering to allow each lamp to warm up for 2 minutes.
Tilt the floodlights group through the lever (Fig. 8-B). It is possible a tilt of about 41°.
(Fig. 8)
In case of accidental putting out it is necessary to wait the cooling of the lamp (about 15
minutes) before a new lighting, because of the high tension that would be necessary for a
hot ignition.
8-A
8-B
8-C
8-C
8-D
8-C
8-C

Table of Contents