EasyManua.ls Logo

PR POWER PR4000 - Replace the Lamp and Floodlight Glass

PR POWER PR4000
75 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
PR4000 9mt 4x1000W METAL HALIDE
54
TL073-11-02-03
01-02-2011
17. REPLACE THE LAMP AND FLOODLIGHT GLASS
In case of replacement of the lamps or the floodlight’s glass, open the floodlight through the 4
stainless steel hooks (1), inserting a screwdriver in the appropriate slots previewed on the hooks.
The hooks are with hingle to support the frame when opened. Replace the lamp or the glass.
Close the floodlight’s glass being careful to position correctly the hooks in their seat.
N.B.: in the 2 inferior floodlights the hooks that support the frame when opened are situated on the
superior side, therefore it is necessary to sustain manually the cover during the operations of
lamp’s replacing.
The use of the NARVA-G.L.E. NACHROMA NCT 1000 W 240 V lamp is recommended. If a lamp
by a different manufacturer is used, the same shall necessarily meet the requirements here below:
Type of lamp: metal halide
Base: E40
Nominal power: 1000 W
Nominal voltage: 240 V 50 Hz
Operating current: 9,5 ÷ 10,5 A
1