PR4000 9mt 4x1000W METAL HALIDE
53
TL073-11-02-03
01-02-2011
FAULT
The lowering telescopic mast lever does not work.
CAUSE
Defective electrical connection.
REMEDY
Check the electrical connection.
CAUSE
The hydraulic gear box is failure.
REMEDY
Unscrewing the pin in counterclockwise direction, make reference to chapter12.2 HYDRAULIC
GEAR BOX”, it is possible to lower the mast.
FAULT
One or more lamps does not light.
CAUSE
Defective or failure lamps.
REMEDY
Before replace the lamp, it is advisable to make a test, installing the lamp that it is presumed
failure in a floodlight with lamp previously working.
FAULT
The lamps fails to light.
CAUSE
The lamps have been accidentally putted out.
REMEDY
The lamps could not be relighted up, it is necessary to wait the cooling of the lamp (about 15
minutes).
CAUSE
The automatic earth leakage relay has been tripped.
REMEDY
Rearme the automatic earth leakage relay.