EasyManua.ls Logo

PR POWER PR4000 - Page 52

PR POWER PR4000
75 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
PR4000 9mt 4x1000W METAL HALIDE
52
TL073-11-02-03
01-02-2011
FAULT
The automatic earth leakage relay trips during the use of the machine.
CAUSE
It has been a leak of current during the use of the auxiliary socket.
REMEDY
Check the electrical system connected to the auxiliary socket, verify that no values of draw are not
exceeds to you.
CAUSE
Electrical connections interrupted.
REMEDY
Check the external electrical system and contact eventually the manifacturer.
CAUSE
Connection to Earth not correctly carried out.
REMEDY
Check that the connection to Earth is adapted.
FAULT
The raising and lowering lever of the telescopic mast does not work.
CAUSE
Defective electrical connection.
REMEDY
Check the electrical connection.
CAUSE
The hydraulic gear box does not work.
REMEDY
Check that the automatic earth leakage relay is armed, eventually rearmed it.
Check that the electrical system of the hydraulic gear box.
Check the oil inside the hydraulic gear box, add it if necessary.
Replace the hydraulic gear box contacting directly the manufacturer.

Table of Contents

Related product manuals