Cleaning Procedure
1. Wipe down equipment using a soft lint-free cloth using only the recommended cleaning
solution. Always spray cleaning solution directly onto the cleaning cloth and not directly
onto the equipment surface to avoid equipment damage due to excessive moisture.
CAUTION: Do not use acidic cleaners and do not spray directly onto the equipment
surfaces.
2. Rinse surfaces using a clean lint-free cloth dampened with water only.
3. Then completely dry with another clean lint-free cloth.
Power Requirements
This machine is an externally powered unit that requires the facility to provide good quality
input power that satisfies the machine specified power requirements.
Equipment Operating Power Specification
l Nominal 120 VAC
1
models
o
Operating voltage: 90 VAC to 132 VAC.
o
AC frequency range: 47 - 65 Hz
2
l Nominal 240 VAC Models
o
Rated Operating voltage: 180 VAC - 264 VAC.
o
Frequency: 47- 65 Hz
Facility Input Power Requirements
The facility must provide a good quality stable power signal (not fluctuating or intermittent) to
insure performance and trouble tree operation.
Individual branch circuit requirement (US and Canada installations)
Each Precor treadmill must be connected to a separate 20 amp individual branch circuit outlet.
No other devices can be connected to the same circuit outlet except for one optional PVS (Per-
sonal Viewing System) display if installed.
l Individual branch circuit: An individual branch circuit provides a hot conductor and
neutral conductor to a receptacle. The conductors must not be looped, "daisy-chained",
or connected to any other conductors or receptacles. The circuit must be grounded
according to NEC guidelines or local region electric codes.
1
voltage in an alternating current circuit
2
The hertz (symbol: Hz) is the derived unit of frequency in the International System of Units
(SI) and is defined as one cycle per second.
Contact Precor Customer Support at support@precor.com or 800.786.8404 with
any questions.
Page 13
2 General Information
Power Requirements

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Precor Experience 700 line Series and is the answer not in the manual?

Precor Experience 700 line Series Specifications

General IconGeneral
BrandPrecor
ModelExperience 700 line Series
CategoryTreadmill
LanguageEnglish

Related product manuals