EasyManua.ls Logo

Precor Experience 700 line Series - Lift Motor Replacement; About; Specification; Lift Motor Fuse

Precor Experience 700 line Series
246 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Lift Motor Replacement
About
This procedure provides instruction to remove and replace the Lift Motor.
Specification
System Component Specification
Lift Motor Calibration Distance* 1 1/8 in - 1 3/16 in (2.8 cm - 3.0 cm)
Note: * Calibration distance is specified at incline level 0.
Lift Motor Fuse
he lift motor fuse (2Amp) is located on the LPCA
1
board in the MC
2
module. Remove the MC
bottom cover to access the fuse. Use a small standard screwdriver to unsnap the clip fasten-
ers and remove the cover.
1
Lower printed circuit assembly; generally this refers to the lower board. On treadmills, this is
the motor controller unit (MCU), and on self-powered units, it is the main board in the lower
section.
2
Motor controller or motor controller module
Contact Precor Customer Support at support@precor.com or 800.786.8404 with
any questions.
Page 147
6 Replacement Procedures
Lift Motor Replacement

Table of Contents

Related product manuals