Lift Motor Replacement
About
This procedure provides instruction to remove and replace the Lift Motor.
Specification
System Component Specification
Lift Motor Calibration Distance* 1 1/8 in - 1 3/16 in (2.8 cm - 3.0 cm)
Note: * Calibration distance is specified at incline level 0.
Lift Motor Fuse
he lift motor fuse (2Amp) is located on the LPCA
1
board in the MC
2
module. Remove the MC
bottom cover to access the fuse. Use a small standard screwdriver to unsnap the clip fasten-
ers and remove the cover.
1
Lower printed circuit assembly; generally this refers to the lower board. On treadmills, this is
the motor controller unit (MCU), and on self-powered units, it is the main board in the lower
section.
2
Motor controller or motor controller module
Contact Precor Customer Support at support@precor.com or 800.786.8404 with
any questions.