EasyManuals Logo

Precor SPINNER CHRONO POWER User Manual

Precor SPINNER CHRONO POWER
197 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #104 background imageLoading...
Page #104 background image
Note:The zip tie that removed and used to hold the Mylar moisture barrier over the
LPCA board is not required to be replaced.
10. (Spinner® Chrono™ Power models only)
If the cross member cable ties were removed, replace them with new cable ties to
secure the generator, data COMM, strain gauge , and battery interface cables to the
cross member (4x locations).
11. Place the generator belt onto the generator and flywheel generator pulleys. Place the
belt onto the smaller generator pulley and walk the belt onto the larger flywheel gen-
erator pulley
12. Adjust the drive belt tension and tracking to specification, go to "Drive Belt Tension
and Tracking Adjustment" on page27
Contact Precor Customer Support at support@precor.com or 800.786.8404 with
any questions.
Page 96
5 Replacement Procedures
Drive Belt, Generator Belt, and Flywheel Replacement

Table of Contents

Other manuals for Precor SPINNER CHRONO POWER

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Precor SPINNER CHRONO POWER and is the answer not in the manual?

Precor SPINNER CHRONO POWER Specifications

General IconGeneral
BrandPrecor
ModelSPINNER CHRONO POWER
CategoryExercise Bike
LanguageEnglish

Related product manuals