40 A26361-K878-Z102-2-7619
Switching the Server ON and OFF Preparation for Use and Operation
Switching the server OFF
Power-on indicator (position 7 in figure 16 on page 42) lights green.
Ê Shut down the operating system in an orderly manner.
Ê Press the ON/OFF button (position 6 in figure 16 on page 42) and/or send a
corresponding control signal (see “Other ON/OFF options” on page 40).
The server switches OFF and remains in standby mode.
Other ON/OFF options
In addition to the ON/OFF button, the server can be switched ON and OFF in
the following ways:
– Specified switch-on time/switch-off time
The server is switched ON or OFF at a time specified in the ServerView
program
– Ring indicator
The server is switched ON via an internal or external modem.
– Wake On LAN (WOL)
The server is switched on by a command via the LAN (Magic Package).
– After power failure
The server automatically reboots following a power failure (depending of the
settings in the BIOS).
– Power override function
The system can be switched OFF by longer pressing (approx. 4-5 sec.) the
ON/OFF button.
V CAUTION!
There is a risk that data may be lost.