Pos. Name Image Description
■
38 Rear tiller locked (rigid) or
flexible (free)
The rear tiller is locked (rigid) if the indicator lamp lights white
continuously.
■
= Rear tiller locked
■
X = Rear tiller flexible
46 Heater control Automatic or manual
48 Recirculated air in driver's
cab
ON - OFF
49 Temperature or fault dis-
play
The temperature in the driver's cab is displayed here.
■ If
a fault occurs in the heater control, the text "ERROR" ap-
pears in the display.
A detailed fault description is available in the fault log in
menu item B.10.
50 Defrost mode
51 Fan speed control
52 BISON X inclinometer The inclination angles of blade and frame are displayed here.
53 Track setting plate Arrow up = Track setting plate lifted
Arrow down = Track setting plate lowered
Track
setting plate continuously lit white = Track setting plate ac-
tive
Track setting plate continuously lit red = Error
54 Track tiller Track tiller continuously lit green = Track tiller active
Track tiller continuously lit gray = Track tiller not active
Snow groomer BISON
Operating and Maintenance Manual
BISON 908930245 - 30367
6 - Display