This subprogram, as in case of CD1803 control panel, is used to enter RFID and DALLAS IDs. The IDs are assigned
to entered LOGICAL number (from the PBX’s point of view). Unlike older digital systems, no lock code is required
for the operation of IDs.
After entering the A-l subprogram, the message is displayed . Use the identifier you want to assign
to the property. Then the keypad will display a message alternating with the property to which you
have assigned an ID. If you have not yet assigned an ID, a blinking “0” or the number under which the last ID was
entered will be displayed. To assign an ID to this number, press key . If the ID should belong to another
property, press the button and then enter the number and confirm with button .
In order to delete the ID, place it on the keyboard and when the property number is displayed press
(deleting the assignment) and then confirm it with button .
Deletion of all IDs assigned to one property is possible by program A-0 with parameter 99. Each use of program
A-0 requires verification with the installer code.
4.2.1 Controlled adding of IDs by users
In firmware cassettes from version 7r11 it is possible to add RFID and iButton IDs without the interference of
installer in an existing installation, however under the installer’s supervision. In order to save the new ID in the
system, the user should:
1. at idle, enter the number of premises on the keyboard and press the button
2. bring the ID card close to the reader
3. enter the unique code provided by the installer
If the ID has been saved correctly, the cassette will display “Good”.
Note! For the above procedure to function, parameter number 011 must be different from zero (additional code
securing the addition of IDs).
This unique code for ID verification is generated on the basis of:
• installer code in the cassette
• programming code of IDs (parameter No 011)
• number of the premise
• last 4 digits imprinted on the casing of ID card
The code is generated using a script provided by the manufacturer. Addition of IDs is protected by a separate code
defined in parameter 011. For security reasons, this code should be different from the installer’s code. If this
parameter is not defined, it will not be possible to add IDs in this way.
4.2.2 Open programming of IDs
From version 7r63 onwards, the cassette enables to enter the IDs in Open Learn mode, where users add IDs
themselves, without verification by the installer. The procedure runs in two modes:
• entering IDs to the number specified by the user
• entering all IDs into one property