EasyManua.ls Logo

PROEL KDC1905 - Subprogram A-4 - Parameters of Individual Premises

PROEL KDC1905
64 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4.5 Subprogram A-4 — parameters of individual premises
This subprogram enables to change parameters of a given premises (a logical number is used). The available
parameters are listed in Table 6.
Table 6: Options available for individual premises
Table 7: Premises’ flags
+32 and +64 flags enable to call other types of events and use other resources, such as locking or OC.
After entering the subprogram, the cassette will successively receive data for the following parameters
. Parameters with symbol are set as flags. In order to set the appropriate configuration
of these parameters, it is necessary to sum up their weights, which are given in Table 7 .
office mode
lock code lock
mute confirmation of the lock code
feedback blockade
lock opening blockade with button
alternative lock code event
alternative RFID event
forcing impulse addressing
individual ringtone type
individual ringtone volume
Option
Description
automatic opening the lock when handset is raised
blockade on the use of lock code for this property
mute confirmation of the use of lock code in the device
blockade of the use of feedback from the premises
door opening blockade by pressing a button in the device
property generates code(2) code(3) events
assigned IDs generate an RFID event(1)
this property will be addressed using the old method (for pc255)
despite the new type of addressing
individually set ringtone type 0-5
individually set ringtone volume 0-7
Symbol
Option
Bit number
Weight
Office mode
1
+1
Lock code blockade
2
+2
lock code confirmation blockade
3
+4
feedback blockage
4
+8
lock opening blockade with button
5
+16
Alternative event to the lock code (code(2) and code(3))
6
+32
Alternative event to RFID(1)
7
+64
Forcing impulse addressing
8
+128

Table of Contents