AirQ 1570
PERFECTLY SCENTED ENVIRONMENTS
Updated: 2020-03-02
Question and Answer IconNeed help?

Do you have a question about the Prolitec AirQ 1570 and is the answer not in the manual?

Prolitec AirQ 1570 Specifications

Power IconPower
input voltage100 – 240V AC
input current1.5A max
frequency50/60 Hz
internal power15VDC at 4 A
battery typeLithium 3V, #CR2032
Operating Environment IconOperating Environment
working temperature0˚ to 40˚ C
working humidity85% or less
service area per cartridge headUp to 150, 000 cu. ft. (4245 m³)
Capacity IconCapacity
liquid capacity2500mL cartridges
Weight and Dimensions IconWeight and Dimensions
CCU dimensions36cm x 35cm x 17.2cm
cartridge head dimensions35.6cm x 18cm x 17.2cm
CCU weight with 4 modules12 lbs (5.1 kg)
cartridge head weight5 lbs (2.5 kg)

Summary

Chapter 1: IMPORTANT SAFETY INSTRUCTIONS

Appliance Precautions

General safety precautions for using the appliance, including warnings and precautions for fire/electric shock.

Fragrance Cartridge Precautions

Guidelines for handling fragrance cartridges safely, including personal protective equipment and hygiene.

Chapter 2: About AQ1570

Chapter 3: Unpacking

Chapter 4: MOVING AND STORAGE INSTRUCTIONS

Chapter 5: INSTALLATION

General

General information about installation location and requirements for the CCU and cartridge head.

Service Area

Details the effective service area range per cartridge head and CCU placement.

Configuration

Information on mounting the CCU and cartridge heads, including tubing length recommendations.

Estimating Cartridge Life

Guidance on determining cartridge life and the number of heads needed for a space.

Appliance Location

Key placement considerations for optimal performance, including smoke test guidance.

Wall-Mounting AQ1570

Details the components of the mounting kits for drywall, concrete, and sheet metal.

CCU Installation

Steps for installing the CCU enclosure on the wall and connecting power.

Cartridge Unit Installation

Steps for installing the cartridge unit enclosure and assembling the plume kit.

Airline Tubing Installation

Instructions for connecting airline tubing between CCU and cartridge units, and securing it.

Installing an Additional Module

Procedure for connecting and securing an additional module within the CCU.

Chapter 6: OPERATING INSTRUCTIONS

Features and Controls

Overview of the CCU and Cartridge Unit components and their functions.

Setting Up the Cartridge

Step-by-step guide to preparing and installing a fragrance cartridge.

Programming the Appliance

Detailed instructions on setting the clock, modes, and custom programs for the AQ1570.

Using the online SD card programming tool

Guide to creating and managing program sets using Prolitec's online tool.

Loading new firmware from an SD card

Instructions for updating the appliance's firmware using an SD card.

Programming the Appliance from an SD card

Steps for copying program schedules to an SD card for appliance programming.

Copying programs to an SD card

Procedure for saving current appliance programs to an SD card.

Setting Scent Intensity

Guidance on determining and adjusting the scent intensity level for optimal performance.

Scent Control

Method for adjusting scent levels based on detectability and user preference.

The Last Step

Final steps to ensure the appliance is set correctly before closing.

Chapter 7: USER MAINTENANCE

Cartridge Change

Step-by-step instructions for replacing the fragrance cartridge when empty.

Cartridge Change Maintenance Checklist Items

Checklist to diagnose issues like no plume, including power, wipers, and cartridge replacement.

Changing an Appliance

Procedure for dealing with appliance malfunctions, including contacting customer care.

General Care

Guidelines for maintaining and handling the appliance to prevent damage and voiding warranty.

Air Filter and Check Valve

Instructions for replacing the air filter and check valve annually.

Battery Replacement

Procedure for replacing the internal CR2032 battery, typically every two years.

Chapter 8: Applications

Ambient Scenting

Use of scent to create or enhance ambience in public and retail spaces.

Product Marketing

Using scent to promote products at point of sale and in advertising.

Odor Control

Neutralizing odors and replacing them with pleasant scents in various problem areas.

Aromatherapy and Performance Scenting

Utilizing scent to influence emotion, promote well-being, and optimize performance.

Chapter 9: Frequently Asked Questions (FAQs)

Understanding AQ1570 Operation

Covers how the AQ1570 works, room size handling, placement, and adjustment guidelines.

Safety and Usage

Addresses safety concerns regarding children, pets, and general usage practices.

Product Comparisons and Features

Compares AQ1570 to aerosols, highlights eco-friendliness and cartridge switching.

Usage and Maintenance FAQs

Addresses programming schedules, stain prevention, and drip cleanup.

Chapter 10: Specifications

Physical and Electrical Specifications

Covers dimensions, weight, power supply, and working environmental conditions.

Product Compliance and Capacity

Details regulatory approvals, liquid capacity, and service area coverage.

Related product manuals