** The valve spring is coated with CTFE (resistance similar to PTFE)
16.5
Ambient conditions
16.5.1 Ambient temperatures
Data Value Unit
Storage and transport temperature -10 ... +50 °C
Ambient temperature in operation (drive +
motor):
-10 ... +45 °C
16.5.2 Media temperatures
Data Value Unit
Max. temperature, long-term at max. oper‐
ating pressure
50 °C
Max. temperature, for 15 min at max. 2 bar 100 °C
Minimum temperature -10 °C
Data Value Unit
Max. temperature long-term at max. oper‐
ating pressure
45 °C
Max. temperature for 15 min at max. 2 bar 60 °C
Minimum temperature -10 °C
Data Value Unit
Max. temperature long-term at max. oper‐
ating pressure
65 °C
Max. temperature for 15 min at max. 2 bar 100 °C
Minimum temperature -10 °C
Data Value Unit
Max. temperature long-term at max. oper‐
ating pressure
90 °C
Max. temperature for 15 min at max. 2 bar 120 °C
Minimum temperature -10 °C
16.5.3 Air humidity
Data Value Unit
Maximum air humidity*: 95 % relative
humidity
*non-condensing
Pump, compl.
PP liquid end
PC liquid end
PVT liquid end
SST liquid end
Air humidity
Technical data