9.3.4.5
‘Flow control’
‘Menu / Information
è
Settings
è
Inputs/outputs
è
Flow control
è
...’
The setting options for the ‘Flow control’ function are
only available if a flow control is electrically installed. The
symbol for flow control appears:
.
A metering monitor, such as a Flow Control (also DulcoFlow
®
), can reg‐
ister the individual pressure impacts of the pump and report them back to
the pump.
It is possible to switch the function on and off under
‘Activation’
.
The pump switches to fault mode if this feedback isn't provided a certain
number of times in succession as set under
‘Tolerance / strokes’
.
Under
‘at Auxiliary’
, it is possible to set whether the function is to be deac‐
tivated with auxiliary frequency.
Under
‘Signalling’
, you can set whether the control is to trigger an error or
a warning when the tolerance is exceeded.
9.3.4.6
‘Diaphragm rupture’
‘Menu / Information
è
Settings
è
Inputs/outputs
è
Diaphragm rupture
è
...’
The setting options for the ‘Diaphragm rupture’ function
only exist if a diaphragm rupture indicator is electrically
installed. The symbol for diaphragm appears
.
In the
‘Diaphragm rupture’
sub-menu you can select whether the pump
generates a warning message or an error message in the event of a dia‐
phragm rupture.
9.3.5
‘System’
‘Menu / Information
è
Settings
è
System
è
...’
The
‘System’
menu splits into the following sub-menus:
1 -
‘Bluetooth’
2 -
‘Volume unit’
9.3.5.1
‘Bluetooth ’
‘Menu / Information
è
Settings
è
System
è
Bluetooth
è
...’
You can switch the pump’s Bluetooth communication on and off in the
‘Bluetooth’
sub-menu. The blue “Bluetooth active” LED lights up on the
HMI.
Set up /
‘Menu’
55