Proxdata TR515 - 12. What is the maximum number that TR515;TR510 can be served by the software Time Recorder Utility; 13. What is the maximum number of users that can be served by the database of software Time Recorder Utility under the extended mode; 14. If you want TR515;TR510 to send the real time data to MS-SQL server

Default Icon
34 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
12. What is the maximum number that TR515/TR510 can be served by the
software Time Recorder Utility
The number of time recorders connected with the software Time
Recorder Utility is determined by the Windows OS version. For Windows
XP, 10 time recorders are acceptable. For Windows Server version, we
suggest not over 20 time recorders. If the number exceeds, it still can
work (if the Windows OS allows), but will run slowly.
13. What is the maximum number of users that can be served by the
database of software Time Recorder Utility under the extended mode
The number of users depends on the TR.mdb file. This file is up to 2 GB. If
leaving 200 MB for user usage, 10,000 users can be defined.
14. If you want TR515/TR510 to send the real time data to MS-SQL server
The data cant be sent to MS-SQL server directly. Our software Time
Recorder Utility generates the text file (*.txt) with records. To access
MS-SQL server, you need to develop your program to import the text file
into MS-SQL server.