9. Does the same relay work both for the bell and the access control
TR515/TR510 has one relay only. If the relay mode is set to bell (alarm), it
works as bell control only; if the relay mode is set to door lock, it works as
access control only. Use our software to set the relay mode you want.
10. How will it work if the relay mode is set to door lock
Once the relay mode is set to door lock, the door will be open when you
present (swipe) the card to TR515/TR510. Furthermore, if you set “Prefix”
or allowed user in the software Time Recorder Utility, the door will be
open only when you present (swipe) the allowed card to TR515/TR510.
11. If you want to reset TR515/TR510
If you want to use the software TR515 Tool/TR510 Tool to reset it, refer to
“10. If you want to reset TR515/TR510” in the section “About Software
(TR515 Tool/TR510 Tool)” of this document.
If you want to use the software Time Recorder Utility to reset it, refer to
“10. If you want to reset TR515/TR510” in the section “About Software
(Time Recorder Utility)” of this document.
12. Will you lose anything or have to redefine anything after resetting
TR515/TR510
After resetting, the settings in the main board of TR515/TR510 will be
changed to default. However, IP-address will not be changed (for Ethernet
interface type). The records in TR515/TR510 will not be lost.
13. If TR515/TR510 cannot communicate through TCP/IP (for Ethernet
interface type)
Follow the steps as below to set *Transport protocol+ to “TCP” for the
Ethernet module of TR515/TR510.
(1) Connect TR515/TR510 with Hub via WAS-1499 cable.
(2) Power on TR515/TR510.
(1) Disable the firewall and antivirus program in your computer!
(2) Open the software DS Manager (Start\Programs\Tibbo Terminal
Server Toolkit\Tibbo DS Manager). Find your TR515/TR510 on the
“Auto-Discovery” list.