Do you have a question about the Pulsar Measurement Ultra 3 and is the answer not in the manual?
| Brand | Pulsar Measurement |
|---|---|
| Model | Ultra 3 |
| Category | Measuring Instruments |
| Language | English |
This manual provides guidance for correct installation and operation.
Explains how the Ultra 3 operates using ultrasonic pulses and echo detection.
Details the physical, environmental, and performance characteristics of the Ultra 3.
Covers careful unpacking and power supply requirements for the Ultra 3 unit.
Guidance on selecting a safe mounting location and environment for the unit.
Provides dimensions for wall, fascia, and rack mounting configurations.
Illustrates terminal connections for wall, fascia, and rack/panel mounted units.
Details the location of voltage selection switch and mains fuse for power configuration.
Describes the Ultra 3's display, modes of operation, and indicators.
Explains Run Mode, Program Mode, and Test Mode functionalities.
Details the procedure to enter Program Mode using keypad or communicator.
Explains the functions of Hot Keys, Menu Keys, and Numeric Keys.
Guide to navigating the main and sub-menus for parameter adjustments.
Instructions for communicating with the Ultra 3 via RS232 serial interface.
Guides users through entering Program Mode and selecting the Ultra Wizard.
Explains how to choose between Level/Volume, Pump Control, and Flow applications.
Guides initial setup for Level/Volume applications via Quick Setup menu.
Provides detailed examples for level monitoring with alarms and control.
Details the Quick Setup menu for configuring pump applications.
Illustrates sump control and reservoir control scenarios with pump setup.
Guides initial setup for Flow applications via Quick Setup menu.
Describes various primary measuring devices for flow, like flumes and weirs.
Explains absolute and ratiometric calculation methods for different flow devices.
Provides a visual guide to the Ultra 3's menu structure and functions.
Details parameters for application settings, relay configuration, and data logging.
Covers display settings, mA output configuration, and compensation methods.
Explains parameters for stability, echo processing, system settings, and communication setup.
Details simulation and hardware testing procedures for the Ultra 3.
Explains how to configure relay types, functions, and alarm settings.
Details configuration for general control, pump duties, and miscellaneous relays.
Covers volume calculation settings and OCM (Open Channel Measurement) parameters.
Details dimensions required for flow devices and related calculation parameters.
Provides solutions for common symptoms like blank display or incorrect readings.
Guides on the correct and environmentally compliant disposal of device components.