CHAPTER 5 PARAMETER LISTING AND DESCRIPTIONS
Parameter Listing
This chapter describes all the parameters contained within the IMP+.
Application (APP) Menu
P100 Mode of Operation
This parameter sets the mode of operation, when in run mode, and can be
set to one of the following:
Display shows the distance from the transducer face
to the surface.
Display shows how full the vessel is
Display shows how empty a vessel is
Display shows volume of material in the vessel.
P104 Measurement Units
This parameter sets the units you want to use for programming and display
All units of measure are in METRES
All units of measure are CENTIMETRES
All units of measure are in MILLIMETRES
All units of measure are in FEET
All units of measure are in INCHES
P104 Measurement Units
This parameter is to be set to the maximum distance from the face of the
transducer to the empty point, in P104 Measurement Units. Note this value
affects span as well, so should be set before span. Default: IMP 3 = 3.00m
(9.84 feet), IMP 6 = 6.00m (19.69 feet) and IMP 10 = 10.00m (32.81
feet).