Page 163
P821 Totaliser (R)
Displays the current value of the, resettable totaliser. This totaliser can be
allocated to appear, during run mode, on the auxiliary display line (P816)
or alternatively via the “Totaliser” hot key.
P822 Totaliser Decimal Places
This parameter determines the number of decimal places in the totaliser
during run mode. It can be set between 1 and 3. Default = 2
P823 Totaliser Multiplication Factor
Use this parameter if the totaliser increments by to large or small amount,
enter the factor by which the actual flow rate is multiplied by before
incrementing the totaliser.
E.g. if flowrate is being calculated and displayed in ltrs/second and it is
desired to increment the totaliser in cubic metres select 7 = *1000.
When viewing, the totaliser display will state, “Units are: L*1000”, and the
totaliser will be incremented every 1000 litres
Options are: