Engineer Menu’s Clean Start [2020] Clean Start [2000]
Use App No [0] No [0]
System ID Displays unique System ID Displays unique System ID
Cloud Password _ _
Security Level Normal [0] Normal [0]
App Password _ _
Always Poll Cloud No [0] No [0]
Data Network Set Up? 6 6
Programming Signalling . .
ARC Details [1] [1]
Format Not Used [254] Not Used [254]
Digi Channel 1 Fire [0001] Fire [0001]
Digi Channel 2 HU Any [0002] HU Any [0002]
Digi Channel 3 Unconfirmed Any [0018] Unconfirmed Any [0018]
Digi Channel 4 Final Set Any [0022] Final Set Any [0022]
Digi Channel 5 Confirmed Any [0006] Confirmed Any [0006]
Digi Channel 6 Misoperation[0005] Misoperation[0005]
Digi Channel 7 Omit Rearm Any [0017] Omit Rearm Any [0017]
Digi Channel 8 Mains Fail [0052] Mains Fail [0052]
Digi Channel 9 Global Fault 1 [0055] Global Fault 1 [0055]
Digi Channel 10 Test ATS [0064] Test ATS [0064]
Digi Channel 11-16 Not Used [0000] Not Used [0000]
User SMS Signalling
SMS Details [1] [1]
Mobile Number _ _
ALARM RESPONSE
Silent 1
st
Alarm Never [0] Never [0]
Disable Confirm On Entry No [0] No [0]
Area A, B, C, D Starts At Digi [3] Digi [3]
Area A ,B, C, D Stops At Confirm [4] Confirm [4]
Fire, Gas, HU Start At Digi [3] Digi [3]
Fire Stops At Digi [3] Digi [3]
HU Stops at Confirm [4] Confirm [4]
Day Alarm Starts Sirens Only [2] Sirens Only [2]
Day Alarm Stops Sirens Only [2] Sirens Only [2]
SET UP DOWNLOADING
Download By None [0] None [0]
SOFTWARE REVISION
CLEAN START
EXIT ENGINEER MENU

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Pyronix ENFORCER Series and is the answer not in the manual?

Pyronix ENFORCER Series Specifications

General IconGeneral
Frequency868MHz
Operating Temperature-10°C to +40°C
User CodesUp to 50
Battery BackupYes, rechargeable battery
Remote ControlYes, via smartphone app and keyfob
UsersUp to 50
Mobile AppYes
Event LogYes, stores events
Siren OutputYes, built-in and external options
CompatibilityCompatible with Pyronix peripherals

Related product manuals