ENFORCER V11 PROGRAMMING GUIDE
SOAK CONTROL PROGRAMMING
1. Press b or h to scroll to ENGINEER TESTS. Press .
2. Sound to play will be displayed. Press h.
3. Walk Test will be displayed. Press h.
4. Soak Control will be displayed. Press .
5. Select the zones that are required to be soak tested. Each zone should be
entered, following by . Press h once nished.
6. Soak Days Left will be displayed. Select the number of days that the zones
will be left on soak test and press .
7. Initial Soak will be displayed. Enter the number of days the soak test will
revert to in the event a soak zone is triggered during testing. Press .
8. Press h to go back to the Engineer menu.
TEST SIREN, BATTERY LOAD TEST AND OUTPUTS
1. Press b or h to scroll to ENGINEER TESTS. Press .
2. Sound to play will be displayed. Press h.
3. Walk Test will be displayed. Press h.
4. Soak Test will be displayed. Press h.
5. Test Siren will be displayed. Press , any outputs programmed as ‘Siren
Any’ and ‘Strobe Any’ will trigger. Press h to exit.
6. Do Battery Load Test will be displayed. Press to perform a battery
load test, the voltage will be displayed, followed by ‘Battery Passed’ if the test
has been successful. Press h.
7. Test Outputs will be displayed. Press to perform a test on any
output type. For example if ‘0006’ is entered, and the key is pressed, a
‘Conrmed Any’ test will be activated. Press h to cancel the test.
8. Press h to go back to the Engineer menu.
TEST COMMUNICATIONS
1. Press b or h to scroll to ENGINEER TESTS. Press .
2. Sound to play will be displayed. Press h.
3. Walk Test will be displayed. Press h.
4. Soak Test will be displayed. Press h.
5. Test Siren will be displayed. Press h.
6. Do Battery Load Test will be displayed. Press h.
7. Test Outputs will be displayed. Press h.
8. Test Communications will be displayed. Press to send a test signal to
the ARC.
9. Press h to go back to the Engineer Menu.

Table of Contents

Other manuals for Pyronix ENFORCER V11

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Pyronix ENFORCER V11 and is the answer not in the manual?

Pyronix ENFORCER V11 Specifications

General IconGeneral
BrandPyronix
ModelENFORCER V11
CategorySecurity System
LanguageEnglish

Related product manuals