ENFORCER V11 PROGRAMMING GUIDE
COMMUNICATIONS DIAGNOSTICS
1. Pressb or h to scroll to DIAGNOSTICS?. Press .
2. Press h until ‘Communications is displayed and press .
Please note: For more information, please refer to the Communication Guide.
ENGINEER RESTORE OPTIONS
ENGINEER RESTORE OPTIONS?
The Engineer Restore Options are used so that once an alarm has occurred; the system can only be reset by an
engineer code or anti-code.
Engineer Restore of Intruder
If ‘UK Intruder, an Engineer code must be used to reset the system after an alarm. ‘Secure Intruder’ should not be
used.
Engineer Restore of Hold Up
If ‘YES’, an Engineer code must be used to reset the system after an Hold Up, Zone Hold Up, or Duress activation.
Engineer Restore of Tamper
If ‘YES’, an Engineer code must be used to reset the system after a tamper activation.
Engineer Restore of Soak
If ‘YES’, an Engineer code must be used to reset the system after a zone that is on ‘soak’ has triggered when the
system is set.
Engineer Restore of Conrmed
If ‘YES’, an Engineer code must be used to reset the system after a conrmed alarm has occurred.
Engineer Restore of Faults
If ‘YES’, an Engineer code must be used to reset the system after the following faults:
ATE telecom fail
Modem fail
ATE single path fail
Telecom line fail
Battery disconnect
Batt charge
Battery load
Excessive charge
Battery critical
Device fail
Anti-Code Restore
If ‘YES’, the system will display an Anti-Code, to which can be used to generate a special reset code (usually from
the ARC) to reset the system.
Please note: If Anti-Code is selected, this will coincide with the options that have been selected
previously. For example, if ‘Engineer Restore Intruder’ is selected, and Anti-Code is selected, then an anti-
code will be produced on intruder activation.

Table of Contents

Other manuals for Pyronix ENFORCER V11

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Pyronix ENFORCER V11 and is the answer not in the manual?

Pyronix ENFORCER V11 Specifications

General IconGeneral
BrandPyronix
ModelENFORCER V11
CategorySecurity System
LanguageEnglish

Related product manuals