ENFORCER V11 PROGRAMMING GUIDE
COMMUNICATIONS DIAGNOSTICS
1. Pressb or h to scroll to ‘DIAGNOSTICS?’. Press .
2. Press h until ‘Communications’ is displayed and press .
Please note: For more information, please refer to the Communication Guide.
ENGINEER RESTORE OPTIONS
ENGINEER RESTORE OPTIONS?
The Engineer Restore Options are used so that once an alarm has occurred; the system can only be reset by an
engineer code or anti-code.
Engineer Restore of Intruder
If ‘UK Intruder’, an Engineer code must be used to reset the system after an alarm. ‘Secure Intruder’ should not be
used.
Engineer Restore of Hold Up
If ‘YES’, an Engineer code must be used to reset the system after an Hold Up, Zone Hold Up, or Duress activation.
Engineer Restore of Tamper
If ‘YES’, an Engineer code must be used to reset the system after a tamper activation.
Engineer Restore of Soak
If ‘YES’, an Engineer code must be used to reset the system after a zone that is on ‘soak’ has triggered when the
system is set.
Engineer Restore of Conrmed
If ‘YES’, an Engineer code must be used to reset the system after a conrmed alarm has occurred.
Engineer Restore of Faults
If ‘YES’, an Engineer code must be used to reset the system after the following faults:
• ATE telecom fail
• Modem fail
• ATE single path fail
• Telecom line fail
• Battery disconnect
• Batt charge
• Battery load
• Excessive charge
• Battery critical
• Device fail
Anti-Code Restore
If ‘YES’, the system will display an Anti-Code, to which can be used to generate a special reset code (usually from
the ARC) to reset the system.
Please note: If Anti-Code is selected, this will coincide with the options that have been selected
previously. For example, if ‘Engineer Restore Intruder’ is selected, and Anti-Code is selected, then an anti-
code will be produced on intruder activation.