ENFORCER V11 PROGRAMMING GUIDE
DIAGNOSTICS
DIAGNOSTICS?
Wireless Devices?
Wired Devices?
Communications?
Tablet Keypads?
This option enables the engineer to perform full diagnostics on all key wired and wireless components of the
system.
WIRELESS DEVICES
View Inputs
This option views the status of all wireless zones:
O - Open
C - Closed
T - Tamper
F - Fault
S - Supervision fault
B - Battery fault
Signal Strength
This option is used to view the signal strength for any wireless zone, bell or arming station that is learnt to the
system. The signal strength is shown on both the individual wireless device and on the panel in the following
ways:
If a Green LED is shown on the peripheral, the signal strength is HIGH.
If a Red LED is shown on the peripheral the signal strength is LOW / NONE.
Once one of the signal strength menus has been entered, ‘Please Wait will be displayed and a countdown from
300 seconds will begin. This may last up to ve minutes before all of the wireless devices have been analysed.
From this point each device is tested every 15 seconds. On the LCD display it is also possible to view each
individual device’s signal strength as a percentage.
DISPLAY NUMBER SIGNAL STRENGTH SIGNAL PERCENTAGE LED COLOUR ON DEVICE
3 Excellent 80 to 100% Green
2 Good 30 to 80% Green
1 Weak 0 to 30% Red
0 Missing/no signal 0 to 10% Red
? Still testing N/A N/A
Battery Status
This option is used to measure the battery levels for wireless zones and bells. The battery level is shown on the
control panel.
Once the battery status menu has been entered, ‘Please Wait’ will be displayed and a countdown from 300
seconds will begin. This may last up to ve minutes before all of the wireless devices have been analysed. From
this point each device is tested every 15 seconds.
Testing - waiting for a Battery result.
Good - at least one month of battery life remaining.

Table of Contents

Other manuals for Pyronix ENFORCER V11

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Pyronix ENFORCER V11 and is the answer not in the manual?

Pyronix ENFORCER V11 Specifications

General IconGeneral
BrandPyronix
ModelENFORCER V11
CategorySecurity System
LanguageEnglish

Related product manuals