EasyManuals Logo
Home>Pyronix>Security System>ENFORCER V11

Pyronix ENFORCER V11 Programming Guide

Pyronix ENFORCER V11
60 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #17 background imageLoading...
Page #17 background image
17
ENFORCER V11 PROGRAMMING GUIDE
INPUT ATTRIBUTES
Chime
The internal sounder will sound a chime if enabled.
Single
Chimes once when the zone is triggered.
Follow
Chimes when the zone is triggered and only stops once the zone is inactive. To enable/disable the chime in day
mode press c, when a c’ is displayed on the keypad, the chime is enabled.
Omittable
Enables the zone to be manually omitted from the arming procedure.
Double knock
The system will only generate an alarm if this zone is triggered twice within a pre-set period, or if the zone
remains in fault condition for that period.
For the double knock timer, see “Change Timers” on page 24.
Normally open
Enables the system to respond correctly when detectors of ‘normally open’ conguration are programmed to
the system. Alternatively converts input types which default to normally open (e.g. Push to set) to operate with
normally closed devices.
Occupancy
If enabled, and the zone is not triggered before the timer expires, then the programmed action is taken. If
the detector is triggered, timer is reset. The timer can also be programmed to be suspended when the area
containing the zone is armed.
For the occupancy timer and arm suspension, see “Change Timers” on page 24.
To program the actions when the timer expires, see “Occupancy Zones” on page 29.
Monitor activity
Enables the zone to generate a internal alarm and a log entry if the zone does not detect any activity for a period
specied by the NAT (Non Activity Time.)
For the NAT time, see “Change Timers” on page 24.
Special log
Forces a log entry when the zone is opened or closed, even when an alarm does not result. May be selected to
apply when the system is set, when unset, or always.
Supervision
If enabled, the wireless zone is supervised to make sure it is still polling the system. If disabled, there will be no
alert if this zone is out of signal range of the system or stops polling the system.
Conrm group
If zones are programmed into the same conrm group, multiple zones activated in the same conrm group will
only generate an unconrmed alarm signal. If two or more zones in dierent conrm groups are activated within
the conrm time a conrm signal will be generated. This is useful when two or more shock sensors are being
activated by the same event. If a conrm group is selected as ‘00’, the zones are not part of any group.
Hint: Zones programmed into Conrm Group ‘99’ will never contribute to a conrmed alarm signal.
Input description and location
A name and location can be entered here. The name will appear on the display if an alarm has occurred; the
location is used for a more detailed reference if required.

Table of Contents

Other manuals for Pyronix ENFORCER V11

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Pyronix ENFORCER V11 and is the answer not in the manual?

Pyronix ENFORCER V11 Specifications

General IconGeneral
BrandPyronix
ModelENFORCER V11
CategorySecurity System
LanguageEnglish

Related product manuals