ENFORCER V11 PROGRAMMING GUIDE
Tag opens doors
This function is used in conjunction with a reader programmed as ‘Entry Control’.
If ‘YES’ the ‘Entry Control’ readers will control the arming/disarming and access control. If ‘NO’ the Entry Control
readers will control the arming/disarming only.
For programming entry control readers, see “Entry Control or Access Control” on page 23.
Fire Key Enable
If ‘YES’ the re key will be enabled on the keypad.
Set With Polling Fault
If ‘YES’ the system will still arm even if there is a wireless polling fault.
If ‘NO’ the user will not be able to arm the system with a polling fault. The keypad will display a fault and the
arming procedure will be stopped. The zone causing the poll fault can be identied in the event log.
Fob Unset Entry
If ‘YES’ any wireless keyfobs learnt will only be able to disarm the system once the entry time has been started. If
‘NO’ any wireless keyfobs learnt will be able to disarm the system without the entry time being started rst.
Wireless Bell Supervision
If ‘YES’ then wireless external bells will activate they can’t communicate with the system for a period of 2 hours.
Download if Set
If ‘YES’ any upload/download procedures will be possible on the InSite software regardless of the arm/disarm
status of the system.
OCCUPANCY ZONES
This section programs the action(s) the system will take if any zones with the occupancy attribute enabled are not
triggered for the duration of the occupancy timer.
Push notication
If enabled, the system will send a push notication to the smart device application.
Hint: To receive push notications, this option must be enabled and notication type ‘284 No Activity in Property’ must be activated on the users Cloud
account. This can be found in Notications > Alarms.
SMS
If enabled, the system will send an SMS to programmed telephone numbers.
Hint: The occupancy alert SMS event is associated with the alarm option in the SMS event menu. If the Alarm option is selected in the SMS event menu,
and if there is no activity, an SMS text message will be sent to the respective mobile phone. To view the categories, see the Communications Guide.
ARC call
If enabled, the system will send a signal to the programmed ARC.
Hint: To signal an occupancy event to an ARC using Fast Format, one of the Digi outputs needs to be programmed as output type ‘0065 Input Activity Fl’.
Keypad sounder
If enabled, the system will sound all the speakers on keypads and proximity readers.
Internal sounder
If enabled, the system will alert from any internal sounders/speakers on the system.
External sounder
If enabled, the system will sound any external sirens on the system.
For occupancy attribute information, see “Input Attributes” on page 17.
For the occupancy timer and arm suspension, see “Change Timers” on page 24.

Table of Contents

Other manuals for Pyronix ENFORCER V11

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Pyronix ENFORCER V11 and is the answer not in the manual?

Pyronix ENFORCER V11 Specifications

General IconGeneral
App CompatibilityProControl+
Battery BackupYes
Wireless DetectorsYes
Wireless SirenYes
RepeatersYes
Two-Way Wireless TechnologyYes
Operating Temperature-10°C to +40°C
Storage Temperature-20°C to +60°C
Communication OptionsPSTN
Wireless Zones64