54
ENFORCER V11 PROGRAMMING GUIDE
APPENDIX D  OUTPUT TYPES
NO. TYPE ACTIVE RESTORE
0000 Not Used (Permanently o)
0001 Fire At alarm When a valid code is entered
0002 Hold Up Any "At a HU or Duress alarm
(This includes keypad HU)"
When a valid code is entered
0003 Intruder Any At alarm, while system is disarmed At rst valid code entry and at end
of conrm time.
0005 Misoperation Any
(Abort)
When system is silenced after any
‘intruder’ output is triggered
After 2 minutes
0006 Conrmed Any After two intruder alarm activations At next code entry
0007 Tamper Any Any tamper alarm At code entry to silence And at end
of conrm time.
0008 Duress At a Duress alarm (i.e. from a
keypad)
When a valid code is entered
0009 HU Device Any At alarm on a HU input only When a valid code is entered
0010 Gas At alarm When a valid code is entered
0011 Set Fail Pre-set time after start of exit time, if
exit procedure is not complete
At code entry to rearm
0012 Entry Deviation When deviation from entry route
occurs, during entry time
At code entry to disarm
0013 Secure Intruder Any At alarm, after exit time started,
until disarmed
At rst valid code entry and at end
of conrm time.
0014 Siren Any When alarm live When alarm silenced or when siren
timer expires
0016 Strobe Any When alarm live When alarm silenced or when
strobe timer expires
0017 Omit Rearm Any Zone omitted if active (or in
alarm condition) at the end of
conrmation time.
When system disarmed
0018 Unconrmed Any Any intruder alarm At code entry to silence
0021 Exit Starts Any When exit time starts to set FIRST
area
At code entry to unset LAST area
0022 Final Set Any When FIRST area is set At code entry to disarm LAST area
0023 Strobe Set Fail Works similar to output 016, but also res if the set fail timer expires.
0025 Keyswitch disarmed This output turns on for 5 seconds when the system is disarmed via a
keyswitch input (pulsed or latched)
0026 Set with Omit Activates when inputs are omitted on arming
0028 Power Fault Active during low volts and battery faults*. Restores at code entry after
fault cleared.
0029 Conrmed Intruder Any When more than one intruder
alarm activates
At next code entry

Table of Contents

Other manuals for Pyronix ENFORCER V11

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Pyronix ENFORCER V11 and is the answer not in the manual?

Pyronix ENFORCER V11 Specifications

General IconGeneral
App CompatibilityProControl+
Battery BackupYes
Wireless DetectorsYes
Wireless SirenYes
RepeatersYes
Two-Way Wireless TechnologyYes
Operating Temperature-10°C to +40°C
Storage Temperature-20°C to +60°C
Communication OptionsPSTN
Wireless Zones64

Related product manuals