55
ENFORCER V11 PROGRAMMING GUIDE
NO. TYPE ACTIVE RESTORE
0030 Conrmed Hold Up Any When more than one conrmed
hold up activates
At next code entry
0033 Entry/Exit Live during any entry or exit time
0034 Lights When exit or entry timer starts 20 seconds after set/disarmed
procedure completed
0035 Follow Input When input triggers Dependent upon programming
0037 Restore 1 At code entry to set After 3 seconds
0038 Restore 2 At code entry to set When disarmed
0039 PIR Latch 1 When set (and in Walk Test) At alarm, or when disarmed
0040 PIR Latch 2 This is the inverse polarity to PIR Latch 1
0041 Mains Good Output showing the mains is healthy
0042 Detr Indn Enable This output activates during walk test and also when a code is entered to
view indications – staying activated for the time for which the indications
are viewed.
0043 Follow Test New output for alternative bell test by activating SAB
0044 O During Test New output for alternative bell test by activating SAB
0048 Detr Walk Test This output is active during walk test, and will only deactivate when all
detectors have been tested.
0049 Detector Masked
(Not applicable on
grade 2 systems)"
If any detector goes into mask
condition the output will trigger
When masking fault clears.
0050 Follow 24 Hour If any input programmed as “Day
alarm” activates
When input restored
0051 Line Fault When Line Fault signalled by
communicator
When fault clears
0052 Mains Fail After pre-set time without mains
power
On restoration of mains
0053 Battery Faults When battery disconnected or load
fail detected
At next valid code entry
0054 Low Volts When the input voltage from the
transformer is too low
When the control panel reads the
correct voltage.
0055 "Global Fault 1
(Faults: Modem, Battery,
Fuse, Line, Mains)"
At fault When fault clears
0056 "Global Fault 2
(Faults: as above)"
Activates if fault occurs only when
system is armed
When all faults cleared
0058 Guard Code Used When guard’ code accepted After 60 seconds
0059 Engineer Access When entering Engineer Mode Leaving Engineer Mode
0060 Initialise Digi At power up Live for 45 seconds only
0063 Test ATE/GSM Test signalling through PSTN and
GSM. Activates when a test call is
sent.(Only used for specic GSMs)
When test completed

Table of Contents

Other manuals for Pyronix ENFORCER V11

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Pyronix ENFORCER V11 and is the answer not in the manual?

Pyronix ENFORCER V11 Specifications

General IconGeneral
BrandPyronix
ModelENFORCER V11
CategorySecurity System
LanguageEnglish

Related product manuals