Remote Commands
R&S
®
FSVA3000/ R&S
®
FSV3000
1197User Manual 1178.8520.02 ─ 01
<li> Limit line
<t> irrelevant
Parameters:
<TraceNumber> 1 to 6
*RST: 1
Example:
CALC:LIM2:TRAC 3
Assigns limit line 2 to trace 3.
DISPlay[:WINDow<n>]:STATe <State>
This command changes the display state of the selected measurement window.
Note that this command is maintained for compatibility reasons only. Use the LAYout
commands for new remote control programs
(See Chapter 14.6.2, "Working with Windows in the Display", on page 876).
Suffix:
<n>
.
Window
Parameters:
<State> ON | OFF | 0 | 1
OFF | 0
Switches the function off
ON | 1
Switches the function on
DISPlay[:WINDow<n>]:TYPE <WindowType>
This command selects the results displayed in a measurement window.
Note that this command is maintained for compatibility reasons only. Use the LAYout
commands for new remote control programs (see Chapter 14.6.2, "Working with Win-
dows in the Display", on page 876).
The parameter values are the same as for LAYout:ADD[:WINDow]? on page 876.
Suffix:
<n>
.
Window
Parameters:
<WindowType> DIAGram | RSUMmary | MTABle | PEAKlist | SGRam
HCOPy:ITEM:ALL
This command is maintained for compatibility reasons only. It has no effect.
SOURce<si>:EXTernal<gen>:FREQuency:SWEep[:STATe] <State>
Note that this command is maintained for compatibility reasons only. It is not required
in new remote control programs.
Deprecated Commands

Table of Contents

Other manuals for R&S FSV3030

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the R&S FSV3030 and is the answer not in the manual?

R&S FSV3030 Specifications

General IconGeneral
BrandR&S
ModelFSV3030
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals