Alarm messages and possible causes
99
6
6 Alarm messages and possible causes
Various alarm messages can be displayed on the control unit display.
6.1 Alarm message meanings
No. Message on display Meaning
Possible cause
1 Fault in dosing system. Stop! The metering system actuator cannot reach
the target value.
Blockage
No position feedback
2 Maximum outlet reached!
Speed or application rate too
high
Metering slider alarm
The maximum metering opening is
reached.
The set application rate (+/- quantity) ex-
ceeds the maximum metering opening.
3 Flow factor is outside limits. The flow factor must lie within a range of
0.40 - 1.90.
The newly calculated or entered flow
factor is outside the range.
4 Hopper left empty. The left level sensor reports "empty".
The left hopper is empty.
5 Hopper right empty. The right level sensor reports "empty".
The right hopper is empty.
7 Data will be deleted!
Delete = START
Cancel = ESC
Safety alarm to prevent the unintentional
deletion of data.
8 Min. quantity (150 kg) not
achieved, old factor valid.
Flow factor calculation not possible.
The application rate is too low to calcu-
late the new flow factor when the re-
maining quantity is weighed.
The old flow factor is retained.
9 Application rate
Min. setting = 10
Max. setting = 3000
Reference to the value range of the Appli-
cation rate
Entered value is not permitted.
10 Working width
Min. setting = 2.00
Max. setting = 50.00
Reference to the value range of the Work-
ing width.
Entered value is not permitted.
11 Flow factor
Min. setting = 0.40
Max. setting = 1.90
Reference to the value range of the flow
factor.
Entered value is not permitted.