4.10.4 Test/diagnosis
The Test/diagnosis menu enables function monitoring and checking of specific
sensors/actuators.
NOTICE
This menu is for information purposes only.
The list of sensors depends on the equipment of the machine.
Sub-menu Meaning Description
Slide test points Test for approaching the various posi-
tion points of the sliders.
Checking the cali-
bration
Metering slide Approaching the left and right meter-
ing slide
Page 75
Voltage Checking the operating voltage.
Level sensor Checking the level sensors
Weigh cells Checking the weigh cells.
M EMC Checking the sensors for the M EMC
function.
Drop point test points Test for approaching the various posi-
tion points of the drop point.
Checking the cali-
bration
Drop point Approaching the drop point.
Linbus Checking the assemblies registered
via LINBUS.
TELIMAT sensor Checking the TELIMAT sensors
Hopper cover Checking the actuators.