Operation QUANTRON-A
33
4
4.3.1 Trip counter
This menu provides the following values:
- spread quantity (kg)
- spread area (ha)
- spread distance (m)
Figure 4.3: Trip counter menu
[1] Display showing spread quantity since the last reset
[2] Display showing spread area since the last reset
[3] Display showing spread distance since the last reset
[4] Clearing the trip counter: all values to 0
Clearing the trip counter:
1. Open the Weighing/Trip counter > Trip counter sub-menu.
The values for spreading quantity, area and distance collected since the
last deletion are displayed.
The Delete trip counter field is highlighted.
2. Press the Enter key.
All of the trip counter values are reset to 0.
3. Press the kg key.
You are taken back to the operating screen.
Checking the trip counter during spreading:
During spreading, i.e. when the slides are open, the Trip counter menu can be
opened to display the current values.
NOTICE
If you wish to continuously monitor the values during spreading, freely selecta-
ble operating screen display fields may also be assigned the kg Trip, ha Trip
or mTrip values, see chapter 4.10.2: Display configuration, page 72
.
1
2
4
3

Table of Contents