Operation QUANTRON-A 4
58
4.7.2 AUTO/MAN mode
The default operating mode is AUTO. The control unit automatically controls the
actuators based on the speed signal.
The manual mode is only applied in the following cases:
there is no speed signal (radar or wheel sensor not available or defective),
application of slug pellets or seeds (fine seeds).
Operating mode selection
1. Switch on the QUANTRON-A control unit.
2. Open the Machine settings > AUTO/MAN mode menu.
3. Select the required menu item.
4. Press the Enter key.
5. Follow the instructions on the screen.
Important information on the use of the operating modes during spreading op-
eration is provided in chapter 5: Spreading operation with the QUANTRON-A
control unit, page 87.
AUTO km/h + AUTO kg: automatic operation with automatic mass flow con-
trol:
The AUTO km/h + AUTO kg operating mode continuously controls the fertiliser
quantity during spreading according to the forward speed and the fertiliser’s flow
behaviour. This optimises the metering of the fertiliser.
NOTICE
To ensure regular spreading of the spreading material in manual operating
mode, it is imperative to work with a constant forward speed.
Menu Meaning Description
AUTO km/h + AUTO kg AXIS only: Selecting the automatic
mode with automatic weighing
Page 58
AUTO km/h Selection of automatic mode Page 92
MAN scale Metering slide adjustment for manual
mode
Page 94
MAN km/h Adjustment of forward speed for man-
ual mode
Page 93
NOTICE
The specified operating mode is displayed in the operating screen.