Wuhan Raycus Fiber Laser Technologies Co., Ltd.
User Guide of RFL-C3000XZ~RFL-C12000XZ
70
4
Wait for sync
signal dropping
Null
5
Wait
065000ms (int)
5
GOTO
0
99
line
-1
Switch at low
sync signal
Jump to different line when comply
0
99
line
-2
Switch at high
sync signal
Jump to different line when comply
0
99
line
01000000
Switch at waiting
time due
Jump to different line when comply
6
OUT
1
SO
1
sync signal low
level output
2
sync signal high
level output
7
EXT
Power
1
010V
2