EasyManua.ls Logo

Raymarine Element - Grounding - Dedicated Drain Wire; Power Distribution

Raymarine Element
92 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
GroundingDedicateddrainwire
Thepowercablesuppliedwiththisproductincludesadedicatedshield(drain)wireforconnectionto
avessel's
RFgroundpoint.
ItisimportantthataneffectiveRFgroundisconnectedtothesystem.Asinglegroundpointshould
beusedforallequipment.Theunitcanbegroundedbyconnectingtheshield(drain)wireofthe
powercabletothevessel'sRFgroundpoint.OnvesselswithoutanRFgroundsystemtheshield
(drain)wireshouldbeconnecteddirectlytothenegativebatteryterminal.
Thedcpowersystemshouldbeeither:
Negativegrounded,withthenegativebatteryterminalconnectedtothevessel'sground.
Floating,withneitherbatteryterminalconnectedtothevessel'sground
Powerdistribution
Recommendationsandbestpractice.
Theproductissuppliedwithapowercable,eitherasaseparateitemoracaptivecable
permanentlyattachedtotheproduct.Onlyusethepowercablesuppliedwiththeproduct.Do
NOTuseapowercabledesignedfor,orsuppliedwith,adifferentproduct.
Refertothe
Powerconnection
sectionformoreinformationonhowtoidentifythewiresinyour
product’spowercable,andwheretoconnectthem.
Seebelowformoreinformationonimplementationforsomecommonpowerdistributionscenarios:
Important:
Whenplanningandwiring,take intoconsiderationotherproductsinyoursystem,someofwhich
(e.g.sonarmodules)mayplacelargepowerdemandpeaksonthevessel’selectricalsystem,
whichmayimpactthevoltageavailabletootherproductsduringthepeaks.
Theinformationprovidedbelowisforguidanceonly,tohelpprotectyourproduct.Itcovers
commonvesselpowerarrangements,butdoesNOTcovereveryscenario.Ifyouareunsure
howtoprovidethecorrectlevelofprotection,pleaseconsultanauthorizedRaymarinedealeror
asuitablyqualifiedprofessionalmarineelectrician.
Implementationconnectiontodistributionpanel(Recommended)
1
Waterproof fuseholdercontainingasuitably-ratedinlinefusemustbefitted.
Forsuitablefuserating,referto:
In-linefuseandthermalbreakerratings
.
2
Productpowercable.
3
Drainwireconnectionpoint.
Itisrecommendedthatthesuppliedpowercableisconnectedtoasuitablebreaker orswitchon
thevessel'sdistributionpanelorfactory-fittedpowerdistributionpoint.
Thedistributionpointshouldbefedfromthevessel’sprimarypowersourceby8AWG(8.36mm
2
)
cable.
Ideally,allequipmentshouldbewiredtoindividualsuitably-ratedthermalbreakersorfuses,with
appropriatecircuitprotection.Wherethisisnotpossibleandmorethan1itemofequipmentshares
abreaker,useindividualin-linefusesforeachpowercircuittoprovidethenecessaryprotection.
Connections39

Table of Contents

Related product manuals