1
Waterproof fuseholdercontainingasuitably-ratedinlinefusemustbefitted.
Forsuitablefuserating,referto:
In-linefuseandthermalbreakerratings
.
2
Productpowercable.
3
Drainwireconnectionpoint.
BatteryconnectionscenarioA:
SuitableforavesselwithacommonRFgroundpoint.Inthisscenario, ifyourproduct’spowercableis
suppliedwithaseparatedrainwirethenitshouldbeconnectedtothevessel’scommongroundpoint.
BatteryconnectionscenarioB:
Suitableforavesselwithoutacommongroundingpoint.Inthiscase,ifyourproduct’spowercableis
suppliedwithaseparatedrainwirethenitshouldbeconnecteddirectlytothebattery’snegative
terminal.
Powercableextension
Ifyouneedtoextendthelengthofthepowercablesuppliedwithyourproduct,ensureyouobserve
thefollowingadvice:
Thepowercableforeachunitinyoursystemshouldberunasaseparate,singlelengthof2-wire
cablefromtheunittothevessel'sbatteryordistributionpanel.
Forpowercableextensions,aminimumwiregaugeof16AWG(1.31mm
2
)isrecommended.For
cablerunslongerthan15meters,youmayneedtoconsiderathickerwiregauge(e.g.14AWG
(2.08mm
2
),or12AWG(3.31mm
2
)).
Animportantrequirementforalllengthsofpowercable(includinganyextension)istoensurethat
thereisacontinuousminimumvoltageattheproduct’spowerconnectorof10.8Vdc,witha
fullyflatbatteryat11Vdc.
Important:
Beawarethatsomeproductsinyoursystem(suchassonarmodules)cancreatevoltagepeaks at
certaintimes,whichmayimpactthevoltageavailabletootherproductsduringthepeaks.
Grounding
Ensurethatyouobserveanyadditionalgroundingadviceprovidedintheproduct’s documentation.
Moreinformation
Itisrecommendedthatbestpracticeisobservedinallvesselelectricalinstallations,asdetailed
inthefollowingstandards:
BMEACodeofPracticeforElectricalandElectronicInstallationsinBoats
Connections