Chapter 4: SPX-5 Tiller system settings 55
Turn rate limit
This limits your boat’s rate of turn under SPX-5 Tiller system control.
Off course angle
This screen determines the angle used by the OFF COURSE alarm (see your
Operating Guide
). The OFF COURSE alarm operates if the pilot strays off course by
more than the specified angle for more than 20 seconds.
Screen Text Options
RESPONSE
Range = 1 to 9
Level 1 to 3 minimizes the amount of pilot activity. This conserves
power, but may compromise short-term course-keeping accuracy
Level 4 to 6 should give good course keeping with crisp, well con-
trolled turns under normal operating conditions
Level 7 to 9 gives the tightest course keeping and greatest rudder
activity (and power consumption). This can lead to a rough passage
in open waters as the SPX-5 Tiller system may ‘fight’ the sea.
Screen Text Range
TURN RATE
1° to 30° per second in 1° steps
Screen Text Range
OFF COURSE
15° to 40° in 1° steps
Locked heading
Boat heading
15˚ minimum
D10648-1