EasyManua.ls Logo

Raymarine YachtSense Link - Power Connection and Distribution

Raymarine YachtSense Link
94 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
3.RayNet
toRayNet(SeaTalkhs®)networkcable.
4.SeaTalkng®spurcable.
5.SeaTalkng®powercable(supplying12Vdcpower.5ampinlinefuse
isrequired).
6.SeaTalkng®toDeviceNetspurcable.
7.SeaTalkng®backbone.
5.5YachtSenseecosystem
Y achtSenseisRaymarine’sdigitalmonitoringandcontrolsolution.The
Y achtSenseecosystemenablesonandoffboatmonitoringandcontrolof
connectedvesselsystemsanddata.Onboatmonitoringandcontrolcanbe
achievedusingaRaymarineAxiomMFDortheRaymarineappinstalledon
amobilephoneortablet.Offboatmonitoringandcontrolcanbeachieved
usingtheRaymarineapp.Offboatmonitoringandcontrolrequiresavalid
premiumsubscription.
ThefullYachtSense ecosystemconsistof:
Y achtSenseLinkrouter
Y achtSenseDigitalControlSystem
Raymarinemobileapp
Premiumappsubscription(requiredforoff-boatconnectivity)
AxiomMFDs
Note:
TheY
achtSense
LinkroutermustbeconnectedtothesameSeaTalkng
backboneandastheY achtSenseDigitalControlSystemandanyMFDs.
TherouteralsorequiresaRayNetconnectiontotheYachtSenseDigital
ControlSystem’smastermoduleandanyMFDs.
5.6Powerconnection
Thesuppliedpowercablemustbeconnectedtoa12Vdcor24Vdcpower
supply,thiscanbeachievedbyconnectingdirectlytoabattery,orviathe
distributionpanel.
1.Y achtSenseLink
2.Powercable(supplied)
3.Drainwireconnectstovessel’sRFgroundpoint,ifnogroundpointis
availableconnecttothebatterynegative(-)terminal.
4.Negativewireconnectstopowersupplynegative(-)terminal.
36